Part Number Hot Search : 
IPP100N NJU7600 CY7C0 BUY23 MN101 MG9410 15000 ATC100B
Product Description
Full Text Search
 

To Download CBW2448T5-1000HS Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 1 of 34 size: weight: 2.00 x 1.00 x 0.40 inches 1.07oz (30.5g) 50.8 x 25.4 x 10.2 mm options : ? ? features ? high efficiency up to 91 % ? remote on/off control ? 1600vdc i/o isolation ? six - sided continuous shielding ? single , dual , a nd triple outputs ? fixed switching frequency ? 4:1 ultra wide input voltage ranges ? protection: scp / ovp / olp / otp ? up to 30 watts output power ? standard 2.00? x 1.00? x 0.40? package ? wide operating temperature range : - 40c to +85 c ? compliant to rohs eu direc tive 2011/65/eu ? ul60950 - 1, en60950 - 1, & iec60950 - 1 safety approvals ? description the cbw series of dc/dc power converters offers up to 30 watts of output po wer in an industry standard 2.00? x 1.00? x 0.40 ? package . this series has single, dual , and triple output models with 4 :1 ultra wide input voltage ranges o f 9 - 36vdc and 18 - 75vdc. some features include high efficiency up to 91 %, 1600vdc i/o isolation, six - sided shielding, and remote on/off control. these converters are also prote cted against short circuit, over voltage, over load, and over temperature conditions. all models are rohs compliant and have ul60950 - 1, en60950 - 1, and iec60950 - 1 safety approvals. this series is best suited for use in wireless networks, telecom/datacom, in dustry control systems, measurement equipment, and semiconductor equipment. model selection table single output models model number input voltage output voltage output current no load input current ripple & nois e output power maximum capacitive load ef ficiency min. load full load cbw24s1.5 - 8500 24 vdc (9 - 36 vdc) 1.5 vdc 0ma 8500ma 70ma 100mvp - p 12.75w 20000f 80% cbw24s2.5 - 8000 2.5 vdc 0ma 8000ma 70ma 100mvp - p 20w 20000f 83% cbw24s3.3 - 7500 3.3 vdc 0ma 7500m a 70ma 100 mvp - p 24.75w 20 000 f 86 % cbw24s5 - 6000 5 vdc 0ma 6000m a 105ma 100 mvp - p 30w 144 00f 88 % cbw24s5.1 - 6000 5.1 vdc 0ma 6000ma 105ma 100mvp - p 30.6w 14400 f 88% cbw24s12 - 2500 12 vdc 0ma 2500m a 20ma 15 0mvp - p 30w 3000 f 89 % cbw24s15 - 2000 15 vdc 0ma 2000m a 30ma 15 0mvp - p 30w 2 00 0f 89 % cbw48s1.5 - 8500 48 vdc (18 - 75 vdc) 1.5 vdc 0ma 8500ma 3 0ma 100mvp - p 12.75w 20000f 80% cbw48s2.5 - 8000 2.5 vdc 0ma 8000ma 45 ma 100mvp - p 20w 20000f 84 % cbw48s3.3 - 7500 3.3 vdc 0ma 7500m a 45 ma 100 mvp - p 24.75w 20 000f 8 6 % cbw48s5 - 6000 5 vdc 0m a 6000m a 6 5ma 100 mvp - p 30w 144 00f 88 % cbw48s5.1 - 6000 5.1 vdc 0ma 6000ma 6 5ma 100mvp - p 30.6w 14400 f 88% cbw48s12 - 2500 12 vdc 0ma 2500m a 6 0ma 15 0mvp - p 30w 3000 f 90 % cbw48s15 - 2000 15 vdc 0ma 2000m a 5 0ma 15 0mvp - p 30w 2 000f 91 % dual output models mo del number input voltage output voltage output current no load input current ripple & nois e output power maximum capacitive load efficiency min. load full load cbw24d5 - 3000 24 vdc (9 - 36 vdc) 5 vdc 0ma 3000ma 90ma 100mvp - p 30w 3000f 88% cb w24d12 - 1250 12 vdc 0ma 1250ma 25ma 150mvp - p 30w 2000f 87% cbw24d15 - 1000 15 vdc 0ma 1000ma 25ma 150mvp - p 30w 1300f 87% cbw48d5 - 3000 48 vdc (18 - 75 vdc) 5 vdc 0ma 3000ma 50ma 100mvp - p 30w 3000f 88% cbw48d12 - 1250 12 vdc 0ma 1250ma 15ma 1 50mvp - p 30w 2000f 88% cbw48d15 - 1000 15 vdc 0ma 1000ma 15ma 150mvp - p 30w 1300f 88% triple output models model number input voltage output voltage output current no load input current ripple & nois e output power maximum capacitive load efficiency min. load full load cbw24t3.312 - 26 24 vdc (9 - 36 vdc) 3.3 / 12 vdc 500ma / 42ma 5000ma / 416ma 105ma 50 / 75 mvp - p 26.5w 15000f / 340f 87% cbw24t3.315 - 26 3.3 / 15 vdc 500ma / 33ma 5000ma / 333ma 105ma 50 / 75 mvp - p 26.5w 15000f / 22 0f 87% cbw24t512 - 30 5 / 12 vdc 400ma / 42ma 4000ma / 416ma 105ma 50 / 75 mvp - p 30w 8000f / 340f 88% cbw24t515 - 30 5 / 15 vdc 400ma / 33ma 4000ma / 333ma 105ma 50 / 75 mvp - p 30w 8000f / 220f 88% cbw48t3.312 - 26 48 vdc (18 - 75 vdc) 3.3 / 1 2 vdc 500ma / 42ma 5000ma / 416ma 55ma 50 / 75 mvp - p 26.5w 15000f / 340f 87% cbw48t3.315 - 26 3.3 / 15 vdc 500ma / 33ma 5000ma / 333ma 55ma 50 / 75 mvp - p 26.5w 15000f / 220f 87% cbw48t512 - 30 5 / 12 vdc 400ma / 42ma 4000ma / 416ma 55ma 50 / 75 mvp - p 30w 8000f / 340f 88% cbw48t515 - 30 5 / 15 vdc 400ma / 33ma 4000ma / 333ma 55ma 50 / 75 mvp - p 30w 8000f / 220f 88%
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 2 of 34 specifications: cbw series all specifications are based on 25c, nominal input voltage, and maximum output current unles s otherwise noted. we reserve the right to change specifications based on technological advances. specification test conditions min typ max unit input specifications input voltage range 24 vdc nominal input models 9 24 36 vdc 48 vdc nominal input models 18 48 75 start - up voltage 24 vdc nominal input models 9 vdc 48 vdc nominal input models 18 shutdown voltage 24 vdc nominal input models 8 vdc 48 vdc nominal input models 16 input surge voltage (1 00ms ) 24 vdc nominal input models 50 vdc 48 vdc nominal input models 100 input current no load see table input filter pi type input reflected ripple current 20 map - p output specifications output voltage see table voltage accuracy single output models - 1.0 +1.0 % dual output models - 1.0 +1.0 % triple output models main - 1 .0 +1 .0 % auxiliary - 5 . 0 +5 .0 line regulation low line to high line at full load single output models - 0.2 +0.2 % dual output models - 0.2 +0.2 % triple output models main - 1 .0 +1 .0 % auxili ary - 5 .0 +5 .0 load regulation min load to full load single output models - 0.5 +0.5 % dual output models - 1.0 +1.0 % triple output models main - 1 .0 +1 .0 % auxiliary - 5 .0 +5 .0 cross regulation (dual output models) asymmetrical load 25% / 100% full load - 5.0 +5.0 % voltage adjustability (single output only) see page 4 - 1 0 +10 % output power see table output current see table minimum load see note 3 see table maximum capacitive load minimum input and constant resistive load see tabl e ripple & noise 20mhz bw and with a 1f/50v mlcc single output models see table 20mhz bw and with a 1f/50v mlcc dual output models see table 20mhz bw and with a 0.1f/50v mlcc triple output models see table transient response recovery time 25% load step change 250 s start - up time nominal input and c onstant resistive load power up 30 ms remote on/off 30 temperature coefficient - 0.02 +0.02 %/c remote on/off control (see note 2) positive logic (standard) the ctrl pin voltage is r efere nced to ? input dc/dc on open or 3v < vr < 12v dc/dc off short or 0 < vr < 1.2vdc negative logic (optional) the ctrl pin voltage is r eferenced to ? input dc/dc on short or 0 < vr < 1.2vdc dc/dc off open or 3v < vr < 12v input current of remote contro l pin nominal input - 0.5 +0.5 ma remote off state input current nominal input 3 ma protection short circuit protection continuous , automatic recovery over load protection % of full load at nominal input 150 % over voltage protection zener diode clamp 1.5v output models 2.0 vdc 2.5v output models 3.3 vdc 3.3v output models 3.9 vdc 5v, 5.1v, and 5v output models 6.2 vdc 12v & 12v output models 15 vdc 15v & 15v output models 18 vdc over temperature protection + 115 c
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 3 of 34 specifications: cbw series all specifications are based on 25c, nominal input voltage, and maximum output current unless otherwise noted. we reserve the right to change specifications based on technological advances. specification test conditions mi n typ max unit general specifications efficiency nominal input voltage and full load see table switching frequency single & dual output models 387 430 473 khz triple output models 360 400 440 isolation voltage 1 minute input to output 1600 vdc input to case 1600 output to case 1600 isolation resistance 500vdc 1 g 12 c/w natural convection with heatsink 10 relative humidity 5 95 % rh thermal shock mil - std - 810f vibration mil - std - 810f mtbf single & dual output models bellcore tr - nwt - 000332 case 1: 50% stress, ta=40c 3,163,000 hours mil - hdbk - 217f notice 2, ta=25c, full load (g/b, controlled environment) 434,700 triple output models bellcore tr - nwt - 000332 case 1: 50% stress, ta=40c 2,904,000 hours mil - hdbk - 217f notice 2, ta=25c, full load (g/b, controlled environment) 318,400 physical specifications weight 1.07oz (30.5 g) dimensions (l x w x h) 2.00 x 1.00 x 0.40 inch (50.8 x 25.4 x 10.2 mm) case material nickel - coated copper b ase material fr4 pcb potting material epoxy (ul94 - v0) shielding six - sided case grounding connect case to ? input with decoupling y cap safety & emc characteristics safety approvals iec60950 - 1, ul60950 - 1, en60950 - 1 emi (see note 4 ) en55022 class a esd en61000 - 4 - 2 air 8kv and contact 6kv perf. criteria a radiated immunity en61000 - 4 - 3 1 0 v/m perf. criteria a fast transient (see note 5 ) en61000 - 4 - 4 2kv perf. criteria a surge (see note 5 ) en61000 - 4 - 5 1 kv perf. criteria a conducted immunity en61000 - 4 - 6 10 vrms perf. criteria a notes 1. heat sink is optional. to order the module with a heatsink please add the suffix ?hs? to the model number (ex: cbw24s12 - 2500hs). 2. positive remote on/off control is standard; for negative remote on/off please add the suffix ?r? to the model number (ex: cbw24s12 - 2500r). 3. triple output models require a minimum loading on the output to maintain all specified regulations. operation und er no - load conditions will not damage these devices; however, the y may not meet all listed specifications. 4 . the cbw series standard models can only meet en55022 class a and class b with external components added. 5 . an external input filter capacitor is required if the module has to meet en61000 -4 - 4, en61000 -4 - 5. - 24vdc nomi nal input models: nippon chemi - con ky series, 330f/5 0v - 48vdc nominal input models: nippon chemi - con ky series, 220f/100v caution: this power converter is not internally fused. an input line fuse must always be used. due to advances in techno logy, specifications subject to change without notice.
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 4 of 34 output voltage adjustment output voltage adjustability is for single output models only. o utput voltage set - point adjustment allows the user to increase or decrease the output voltage set - p oint of a module. this is accomplished by connecting an external resistor between the tri m pin and either the +output or ? output pins. with an external resistor between the trim and ? output pins , the output voltage set - point increases. with an external res istor between the trim and +output pins, the output voltage set - point decreases. the external trim resistor needs to be at least 1/16w resistance. trim up trim down cbwxxs1.5 - 8500 cbwxxs2.5 - 8000 trim v out,up r u trim v o ut,up r u 1% 1.515v 4.578 k k k k k k k k k k k 57.930k 36.570k 26.465k .580k 15.577k 9.917k 10.283k 6.585k 7.106k 4.586k 4.988k 3.253k 3.476k 2.302k 2.341k 1.588k 1.459k 1.032k 0.753k 0.588k 38.135k 367.908k 17.368k 165.954k 10.446k 98.636k 6.985k 64.977k 4.908k 44.782k 3.524k 31.318k 2.535k 21.701k 1.793k 1.217k 8.879k 0.755k 4.391k 404.184k 180.592k 106.061k 68.796k 46.437k 31.531k 20.883k 8k 6.687k 1.718k 5.704k 49.641k 2.571k 22.481k 1.527k 13.428k 1.005k 8.902k 0.692k 6.186k 0.483k 4.375k 0.334k 3.082k 0.222k 2.112k 0.135k 1.358k 0.065k k 69.470k 45.533k 31.235k 20.612k 18.490k 12.306k 12.117k 8.152k 8.294k 5.660k 5.745k 3.999k 3.924k 2.812k 2.559k 1.922k 1.497k 1.230k 0.647k 0.676k 47.191k 460.992k 21.431k 207.946k 12.844k 123.597k 8.551k 81.423k 5.975k 56.118k 39.249k 3.031k 27.199k 2.111k 18.162k 1.396k 11.132k 5.509k 223.408k 131.272k 85.204k 39.136k 25.974k 16.102k 8.424k 2.282k
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 5 of 34 mechanical draw ing single & dual output models triple output models
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 6 of 34 characteristic curves *curves for cbw24d5 - 3000. all test conditions are at 25oc. efficiency vs. output load efficiency vs. input voltage, full load power dissipation vs. output load derating output load vs. ambient temp. & airflow vin=vin(nom) typ. output ripple & noise , vin=vin(nom), full load transient response to dynamic load change from 100% to 75% to 100% of full load, vin=vin(nom) typical input start - up & output rise characteristic vin=vin(nom), full load using on/off voltage start - up and vout rise characteristic vin=vin(n om), full load
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 7 of 34 characteristic curves *curves for cbw24d12 - 1250. all test conditions are at 25oc. efficiency vs. output load efficiency vs. input voltage, full load p ower dissipation vs. output load derating output load vs. ambient temp. & airflow vin=vin(nom) typ. output ripple & noise , vin=vin(nom), full load transient response to dynamic load change from 100% to 75% to 100% of f ull load, vin=vin(nom) typical input start - up & output rise characteristic vin=vin(nom), full load using on/off voltage start - up and vout rise characteristic vin=vin(nom), full load
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 8 of 34 characterist ic curves *curves for cbw24d15 - 1000. all test conditions are at 25oc. efficiency vs. output load efficiency vs. input voltage, full load power dissipation vs. output load derating output loa d vs. ambient temp. & airflow vin=vin(nom) typ. output ripple & noise , vin=vin(nom), full load transient response to dynamic load change from 100% to 75% to 100% of full load, vin=vin(nom) typical input start - up & output rise characteristic vin=vin(nom), full load using on/off voltage start - up and vout rise characteristic vin=vin(nom), full load
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 9 of 34 characteristic curves *curves for cbw48d5 - 3000. all test conditions are at 25oc. efficiency vs. output load efficiency vs. input voltage, full load power dissipation vs. output load derating output load vs. ambient temp. & airflow vin=vin(nom) typ. output ripple & noise , vin=vin(nom), full load transient response to dynamic load change from 100% to 75% to 100% of full load, vin=vin(nom) typical input start - up & output rise characteristic vin=vin(nom), full load using on/off voltage start - up and vout rise characteristic vin=vin(nom), full load
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 10 of 34 characteristic curves *curves for cbw48d12 - 1250. all test conditions are at 25oc. efficiency vs. output load efficiency vs. input voltage, full load power dissipation vs. output load derating output load vs. ambient temp. & airflow vin=vin(nom) typ. output ripple & noise , vin=v in(nom), full load transient response to dynamic load change from 100% to 75% to 100% of full load, vin=vin(nom) typical input start - up & output rise characteristic vin=vin(nom), full load using on/off voltage start - u p and vout rise characteristic vin=vin(nom), full load
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 11 of 34 characteristic curves *curves for cbw48d15 - 1000. all test conditions are at 25oc. efficiency vs. output load efficiency vs. input voltage, full load power dissipation vs. output load derating output load vs. ambient temp. & airflow vin=vin(nom) typ. output ripple & noise , vin=vin(nom), full load transient response to dynamic loa d change from 100% to 75% to 100% of full load, vin=vin(nom) typical input start - up & output rise characteristic vin=vin(nom), full load using on/off voltage start - up and vout rise characteristic vin=vin(nom), full load
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 12 of 34 characteristic curves *curves for cbw24s1.5 - 8500. all test conditions are at 25oc. efficiency vs. output load efficiency vs. input voltage, full load power dissipati on vs. output load derating output load vs. ambient temp. & airflow vin=vin(nom) typ. output ripple & noise, vin=vin(nom), full load transient response to dynamic load change from 100% to 75% to 100% of full load, vin= vin(nom) typical input start - up & output rise characteristic vin=vin(nom), full load using on/off voltage start - up and vout rise characteristic vin=vin(nom), full load
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 13 of 34 characteristic curves *curves for cbw24s2.5 - 8000. all test conditions are at 25oc. efficiency vs. output load efficiency vs. input voltage, full load power dissipation vs. output load derating output load vs. ambient temp. & airflow vin=vin(nom) typ. output ripple & noise, vin=vin(nom), full load transient response to dynamic load change from 100% to 75% to 100% of full load, vin=vin(nom) typical inp ut start - up & output rise characteristic vin=vin(nom), full load using on/off voltage start - up and vout rise characteristic vin=vin(nom), full load
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 14 of 34 characteristic curves *curves for cbw24s3.3 - 7500. all test condi tions are at 25oc. efficiency vs. output load efficiency vs. input voltage, full load power dissipation vs. output load derating output load vs. ambient temp. & airflow vin=vin(nom) typ. output ripple & noise, vin=vin(nom), full load transient response to dynamic load change from 100% to 75% to 100% of full load, vin=vin(nom) typical input start - up & output rise characteristic vin=vin(nom ), full load using on/off voltage start - up and vout rise characteristic vin=vin(nom), full load
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 15 of 34 characteristic curves *curves for cbw24s5 - 6000. all test conditions are at 25oc. efficiency vs. output load efficiency vs. input voltage, full load power dissipation vs. output load derating output load vs. ambient temp. & airflow vin=vin(nom) typ. output ripple & noise, vin=vin(nom), ful l load transient response to dynamic load change from 100% to 75% to 100% of full load, vin=vin(nom) typical input start - up & output rise characteristic vin=vin(nom), full load using on/off voltage start - up and vout r ise characteristic vin=vin(nom), full load
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 16 of 34 characteristic curves *curves for cbw24s5.1 - 6000. all test conditions are at 25oc. efficiency vs. output load efficiency vs. input voltage, full load power dissipation vs. output load derating output load vs. ambient temp. & airflow vin=vin(nom) typ. output ripple & noise, vin=vin(nom), full load transient response to dynamic load change f rom 100% to 75% to 100% of full load, vin=vin(nom) typical input start - up & output rise characteristic vin=vin(nom), full load using on/off voltage start - up and vout rise characteristic vin=vin(nom), full load
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 17 of 34 characteristic curves *curves for cbw24s12 - 2500. all test conditions are at 25oc. efficiency vs. output load efficiency vs. input voltage, full load power dissipation vs. outpu t load derating output load vs. ambient temp. & airflow vin=vin(nom) typ. output ripple & noise, vin=vin(nom), full load transient response to dynamic load change from 100% to 75% to 100% of full load, vin=vin(nom) typical input start - up & output rise characteristic vin=vin(nom), full load using on/off voltage start - up and vout rise characteristic vin=vin(nom), full load
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 18 of 34 characteristic curves * curves for cbw24s15 - 2000. all test conditions are at 25oc. efficiency vs. output load efficiency vs. input voltage, full load power dissipation vs. output load derating output load vs. ambient temp. & airf low vin=vin(nom) typ. output ripple & noise, vin=vin(nom), full load transient response to dynamic load change from 100% to 75% to 100% of full load, vin=vin(nom) typical input start - up & output rise characteristic vin=vin(nom), full load using on/off voltage start - up and vout rise characteristic vin=vin(nom), full load
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 19 of 34 characteristic curves *curves for cbw48s1.5 - 8500. all test conditions are at 25oc. efficiency vs. output load efficiency vs. input voltage, full load power dissipation vs. output load derating output load vs. ambient temp. & airflow vin=vin(nom) typ . output ripple & noise, vin=vin(nom), full load transient response to dynamic load change from 100% to 75% to 100% of full load, vin=vin(nom) typical input start - up & output rise characteristic vin=vin(nom), full load using on/off voltage start - up and vout rise characteristic vin=vin(nom), full load
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 20 of 34 characteristic curves *curves for cbw48s2.5 - 8000. all test conditions are at 25oc. efficiency vs. output load effi ciency vs. input voltage, full load power dissipation vs. output load derating output load vs. ambient temp. & airflow vin=vin(nom) typ. output ripple & noise, vin=vin(nom), full load tr ansient response to dynamic load change from 100% to 75% to 100% of full load, vin=vin(nom) typical input start - up & output rise characteristic vin=vin(nom), full load using on/off voltage start - up and vout rise charact eristic vin=vin(nom), full load
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 21 of 34 characteristic curves *curves for cbw48s3.3 - 7500. all test conditions are at 25oc. efficiency vs. output load efficiency vs. input voltage, full load power dissipation vs. output load derating output load vs. ambient temp. & airflow vin=vin(nom) typ. output ripple & noise, vin=vin(nom), full load transient response to dynamic load change from 100% t o 75% to 100% of full load, vin=vin(nom) typical input start - up & output rise characteristic vin=vin(nom), full load using on/off voltage start - up and vout rise characteristic vin=vin(nom), full load
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 22 of 3 4 characteristic curves *curves for cbw48s05 - 6000. all test conditions are at 25oc. efficiency vs. output load efficiency vs. input voltage, full load power dissipation vs. output load d erating output load vs. ambient temp. & airflow vin=vin(nom) typ. output ripple & noise, vin=vin(nom), full load transient response to dynamic load change from 100% to 75% to 100% of full load, vin=vin(nom) typical input start - up & output rise characteristic vin=vin(nom), full load using on/off voltage start - up and vout rise characteristic vin=vin(nom), full load
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 23 of 34 characteristic curves *curves for cbw48s 5.1 - 6000. all test conditions are at 25oc. efficiency vs. output load efficiency vs. input voltage, full load power dissipation vs. output load derating output load vs. ambient temp. & airflow vin=v in(nom) typ. output ripple & noise, vin=vin(nom), full load transient response to dynamic load change from 100% to 75% to 100% of full load, vin=vin(nom) typical input start - up & output r ise characteristic vin=vin(nom), full load using on/off voltage start - up and vout rise characteristic vin=vin(nom), full load
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 24 of 34 characteristic curves *curves for cbw48s12 - 2500. all test conditions are at 25oc. efficiency vs. output load efficiency vs. input voltage, full load power dissipation vs. output load derating output load vs. ambient temp. & airflow vin=vin(nom) typ. output r ipple & noise, vin=vin(nom), full load transient response to dynamic load change from 100% to 75% to 100% of full load, vin=vin(nom) typical input start - up & output rise characteristic vin=vin(nom), full load using on /off voltage start - up and vout rise characteristic vin=vin(nom), full load
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 25 of 34 characteristic curves *curves for cbw48s15 - 2000. all test conditions are at 25oc. efficiency vs. output load efficiency vs. input voltage, full load power dissipation vs. output load derating output load vs. ambient temp. & airflow vin=vin(nom) typ. output ripple & noise, vin=vin(nom), full load transient re sponse to dynamic load change from 100% to 75% to 100% of full load, vin=vin(nom) typical input start - up & output rise characteristic vin=vin(nom), full load using on/off voltage start - up and vout rise characteristic vi n=vin(nom), full load
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 26 of 34 characteristic curves *curves for cbw24t3.312 - 26. all test conditions are at 25oc. efficiency vs. output load efficiency vs. input voltage, full load power dissipation vs. output load derating output load vs. ambient temp. & airflow vin=vin(nom) derating output load vs. ambient temperature with heatsink & airflow, vin=vin(nom) typ. output ripple & noise, vin=vi n(nom), full load transient response to dynamic load change from 100% to 75% to 100% of full load, vin=vin(nom) typical input start - up & output rise characteristic, vin=vin(nom), full load using on/off voltage start - up and vo rise characteristic, vin=vin(nom), full load
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 27 of 34 characteristic curves *curves for cbw24t 3.315 - 26. all test conditions are at 25oc. efficiency vs. output load efficiency vs. input voltage, full load power dissipation vs. output load derating output load vs. ambient temp. & airflow vin=vin(nom) derating output load vs. ambient temperature with heatsink & airflow, vin=vin(nom) typ. output ripple & noise, vin=vin(nom), full load transient response to dynamic load change from 100% to 75% to 100% of full load, vin=vin(nom) typical input start - up & output rise characteristic, vin=vin(nom), full load using on/off voltage start - up and vo rise characteristic, vin=vin(nom), full load
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 28 of 34 characteristic curves *curves for cbw24t 5 1 2 - 30 . all test conditions are at 25oc. efficiency vs. output l oad efficiency vs. input voltage, full load power dissipation vs. output load derating output load vs. ambient temp. & airflow vin=vin(nom) derating output load vs. ambient temperature w ith heatsink & airflow, vin=vin(nom) typ. output ripple & noise, vin=vin(nom), full load transient response to dynamic load change from 100% to 75% to 100% of full load, vin=vin(nom) typical input start - up & output rise characteristic, vin=vin(nom), full load using on/off voltage start - up and vo rise characteristic, vin=vin(nom), full load
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 29 of 34 characteristic curves *curves for cbw24t515 - 30. all test conditions are at 25oc. efficiency vs. output load efficiency vs. input voltage, full load power dissipation vs. output load derating output load vs. ambient temp. & airflow vin=vin(nom) derating ou tput load vs. ambient temperature with heatsink & airflow, vin=vin(nom) typ. output ripple & noise, vin=vin(nom), full load transient response to dynamic load change from 100% to 75% to 100% of full load, vin=vin(nom) t ypical input start - up & output rise characteristic, vin=vin(nom), full load using on/off voltage start - up and vo rise characteristic, vin=vin(nom), full load
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 30 of 34 characteristic curves *curves for cbw48t3.312 - 26 . all test conditions are at 25oc. efficiency vs. output load efficiency vs. input voltage, full load power dissipation vs. output load derating output load vs. ambient temp. & airflow vin=vin(nom) derating output load vs. ambient temperature with heatsink & airflow, vin=vin(nom) typ. output ripple & noise, vin=vin(nom), full load transient response to dynamic load change from 100% to 75% t o 100% of full load, vin=vin(nom) typical input start - up & output rise characteristic, vin=vin(nom), full load using on/off voltage start - up and vo rise characteristic, vin=vin(nom), full load
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 31 of 34 characteristic curves *curves for cbw48t3.315 - 26. all test conditions are at 25oc. efficiency vs. output load efficiency vs. input voltage, full load power dissipation vs. output load derating output load vs. ambient temp. & airflow vin=vin(nom) derating output load vs. ambient temperature with heatsink & airflow, vin=vin(nom) typ. output ripple & noise, vin=vin(nom), full load transient response to d ynamic load change from 100% to 75% to 100% of full load, vin=vin(nom) typical input start - up & output rise characteristic, vin=vin(nom), full load using on/off voltage start - up and vo rise characteristic, vin=vin(nom), full load
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 32 of 34 characteristic curves *curves for cbw48t512 - 30. all test conditions are at 25oc. efficiency vs. output load efficiency vs. input voltage, full load power dissipation vs. output load derating output load vs. ambient temp. & airflow vin=vin(nom) derating output load vs. ambient temperature with heatsink & airflow, vin=vin(nom) typ. output ripple & noise, vin=vin(nom), full load transient response to dynamic load change from 100% to 75% to 100% of full load, vin=vin(nom) typical input start - up & output rise characteristic, vin=vin(nom), full load using on/off voltage start - up and vo rise characteristic, vin=vin(nom), full load
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 33 of 34 characteristic curves *curves for cbw48t515 - 30. all test conditions are at 25oc. efficiency vs. output load efficiency vs. input voltage, full load power dissipation vs. output load derating output load vs. ambient temp. & airflow vin=vin(nom) derating output load vs. ambient temperature with heatsink & airflow, vin=vin(nom) typ. output ripple & noise, vin=vin(nom), full load transient response to dynamic load change from 100% to 75% to 100% of full load, vin=vin(nom) typical input start - up & output rise characteristic, vin=vin(nom), full load using on/off voltage st art - up and vo rise characteristic, vin=vin(nom), full load
r ev d cbw series up to 30 watts, dc/dc power converters 1 1/29/2017 wall industries, inc. ? 37 industrial drive, exeter, nh 03833 ? tel: 603 - 778 - 2300 ? toll free: 888 - 597 - 9255 ? fax 603 - 778 - 9797 website: www.wallindustries.com ? e - mail: sales@wallindustries.com page 34 of 34 model number setup single output models cbw 24 s 12 - 2500 r hs series name input voltage output quantity ouptut voltage output current remote on/off he atsink 24: 9 - 36 vdc s: single output 1.5 1.5v 2000: 2000ma none: positive logic none: no heatsink 48: 18 - 75 vdc 2.5 2.5v 2500: 2500ma r: negative logic hs: with heatsink 3.3: 3.3v 6000: 6000ma 5: 5v 7500: 7500ma 5.1 5. 1v 8000: 8000ma 12: 12v 8500: 8500ma 15: 15v dual output models cbw 24 d 12 - 1250 r hs series name input voltage output quantity ouptut voltage output current remote on/off heatsink 24: 9 - 36 vdc d: dual output 5: 5v 1000: 1000ma none: positive logic none: no heatsink 48: 18 - 75 vdc 12: 12v 1250: 1250ma r: negative logic hs: with heatsink 15: 15v 3000: 3000ma triple output models c bw 24 t 512 - 30 r hs series name input voltage output quantity ouptut voltage output power remote on/off heatsink 24: 9 - 36 vdc t: triple output 3.312: 3.3v / 12v 26: 26.5 watts none: positive logic none: no heatsink 48: 18 - 75 vdc 3.315: 3.3v / 15v 30: 30 watts r: negative logic hs: with heatsink 512: 5v / 12v 515: 5v / 15v company information wall industries, inc. has created custom and modified units for over 50 years. our in - h ouse research and development engineers will provide a solution that exceeds your performance requirements on - time and on budget. our iso9001 - 2008 certification is just one example of our commitment to producing a high quality, well - documented product for our customers. our past projects demonstrate our commitment to you, our customer. wall industries, inc. has a reputation for working closely with its customers to ensure each solution meets or exceeds form, fit and function requirements. we will continue to provide ongoing support for your project above and beyond the design and production phases. give us a call today to discuss your future projects. contact wall industries for further information: phone: ? (603)778- 2300 toll free: ? (888)597 - 9255 fax: ?( 603)778 - 9797 e - mail: sales@wallindustries.com web: www.wallindustries.com address: 37 industrial drive exeter, nh 03833


▲Up To Search▲   

 
Price & Availability of CBW2448T5-1000HS

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X